Part Number Hot Search : 
1SV231 AT49BV N7002 D780232 3PMT10CA CPD106R 273ML SJ100603
Product Description
Full Text Search
 

To Download TR115 Datasheet File

  If you can't view the Datasheet, Please click here to try to view without PDF Reader .  
 
 


  Datasheet File OCR Text:
 TR115
Telecommunications Switch Optocoupler/1 Form A Relay DESCRIPTION
The TR115 is a dual function circuit designed specifically as a telecommunications switch. It consists an optically isolated solid state relay and an optically isolated optocoupler combined in a compact 8pin DIP package. The relay portion is composed of an LED on the input, optically coupled to a sensing circuit which drives two source-to-source DMOS transistors. The optocoupler portion of the package consists of two back-to-back LEDs that drive an output phototransistor.
FEATURES
APPLICATIONS
* * * * * *
Function integration (SSR + Optocoupler) in compact package 20 ohms max on-resistance (Relay Portion) 120mA max continuous load current (Relay Portion) Low input control current (2.5mA TYP, Relay Portion) High Input-Output Isolation Solid State Reliability
* * * * * * * *
Telecom switching PCMCIA cards Fax/modem modules Set-top boxes DAA arrangements Hookswitch Loop current detect Pulse dialing
OPTIONS/SUFFIXES*
ABSOLUTE MAXIMUM RATINGS*
PARAMETER Storage Temperature Operating Temperature Continuous Input Current Transient Input Current Reverse Input Control Voltage Output Power Dissipation UNIT C C mA mA V mW 6 500 MIN -55 -40 TYP MAX 125 85 40 400
* *
-S -TR
Surface Mount Option Tape and Reel Option
NOTE: Suffixes listed above are not included in marking on device for part number identification.
SCHEMATIC DIAGRAM
*The values indicated are absolute stress ratings. Functional operation of the device is not implied at these or any conditions in excess of those defined in electrical characteristics section of this document. Exposure to Absolute Ratings may cause permanent damage to the device and may adversely affect reliability.
APPROVALS
* * *
BABT CERTIFICATE #607835: BS EN 60950, BS EN 41003, BS EN 60065 CSA CERTIFICATE #LR111581-1 UL FILE #E90096
(c) 2004 Solid State Optronics * San Jose, CA www.ssousa.com * +1.408.293.4600
Page 1 of 5
TR115 rev 1.40 (10/25/2004)
TR115
Telecommunications Switch Optocoupler/1 Form A Relay
ELECTRICAL CHARACTERISTICS - 25C
PARAMETER RELAY INPUT SPECIFICATIONS
LED Forward Voltage LED Reverse Voltage Turn-On Current Turn-Off Current V V mA mA 6 1.2 12 2.5 0.5 5 1.5 If = 10mA Ir = 10uA Io = 120mA
UNIT
MIN
TYP
MAX
TEST CONDITIONS
RELAY OUTPUT SPECIFICATIONS
Blocking Voltage Continuous Load Current On-Resistance Leakage Current Output Capacitance Offset Voltage Turn-On Time Turn-Off Time V mA A pF mV ms ms 2 0.5 17 0.2 25 400 120 20 1 50 0.2 5 1 Io = 1uA If = 5mA Io = 120mA Vo = 400V Vo = 25V, f = 1.0MHz If = 5mA If = 5mA, Io = 120mA If = 5mA, Io = 120mA
PHOTOTRANSISTOR INPUT SPECIFICATIONS
LED Forward Voltage Turn-On Current V mA 2 1.2 1.5 If = 10mA Io = 0.5mA
PHOTOTRANSISTOR OUTPUT SPECIFICATIONS
Breakdown Voltage Dark Current Collector-Emitter Capacitance Saturation Voltage Current Transfer Ratio V nA pF V % 30 100 6 0.5 800 60 500 Io = 1uA Vce = 20V Vce = 0V, f = 1.0kHz If = 5mA, Ic = 10mA If = 2mA, Vce = 5V
COUPLED SPECIFICATIONS
Isolation Voltage -H Suffix Isolation Resistance Coupled Capacitance Contact Transient Ratio V V G pF V/ s 2000 7000 2500 3750 100 2 dV = 50V T = 1 minute T = 1 minute
(c) 2004 Solid State Optronics * San Jose, CA www.ssousa.com * +1.408.293.4600
Page 2 of 5
TR115 rev 1.40 (10/25/2004)
TR115
Telecommunications Switch Optocoupler/1 Form A Relay
PERFORMANCE DATA
TR115 Typical Turn-On Time Distribution N = 100, Ambient Temperature = 25C
60 50 40 30 20 10 0 0.085 0.09 0.95 1 1.05 1.1 1.15 1.2 Turn-On Time (ms) 50 Device Count 40 30 20 10 0 0.3 0.35 0.4
TR115 Typical Turn-Off Time Distribution N = 100, Ambient Temperature = 25C
Device Count
0.45
0.5
0.55
0.6
0.65
Turn-Off Time (ms)
TR115 Typical On-Resistance Distribution N = 100, Ambient Temperature = 25C
40 Device Count Device Count 30 20 10 0 15.5 16 16.5 17 17.5 18 18.5 19 On-Resistance (ohms) 50 40 30 20 10 0
TR115 Typical Leakage Current Distribution N = 100, Ambient Temperature = 25C
0.15 0.175 0.2 0.225 0.25 0.275 0.3 0.325 Leakage Current (uA)
TR115 Typical Blocking Voltage Distribution N = 100, Ambient Temperature = 25C
Load Current (mA)
50 Device Count 40 30 20 10 0 380 400 420 440 460 480 500 520 Blocking Voltage (V)
TR115 Maximum Load Current vs. Temperature
140 120 100 80 60 40 20 0
-4 0 -2 0 0 20 40 60 80
Temperature (C)
(c) 2004 Solid State Optronics * San Jose, CA www.ssousa.com * +1.408.293.4600
Page 3 of 5
TR115 rev 1.40 (10/25/2004)
TR115
Telecommunications Switch Optocoupler/1 Form A Relay
MECHANICAL DIMENSIONS 8 PIN DUAL IN-LINE PACKAGE 8 PIN SURFACE MOUNT DEVICE
END VIEW
END VIEW
TOP VIEW
TOP VIEW
BOTTOM VIEW/ BOARD PATTERN
BOTTOM VIEW/ BOARD PATTERN
(c) 2004 Solid State Optronics * San Jose, CA www.ssousa.com * +1.408.293.4600
Page 4 of 5
TR115 rev 1.40 (10/25/2004)
TR115
Telecommunications Switch Optocoupler/1 Form A Relay
DISCLAIMER
Solid State Optronics (SSO) makes no warranties or representations with regards to the completeness and accuracy of this document. SSO reserves the right to make changes to product description, specifications at any time without further notice. SSO shall not assume any liability arising out of the application or use of any product or circuit described herein. Neither circuit patent licenses nor indemnity are expressed or implied. Except as specified in SSO's Standard Terms & Conditions, SSO disclaims liability for consequential or other damage, and we make no other warranty, expressed or implied, including merchantability and fitness for particular use.
LIFE SUPPORT POLICY
SSO does not authorize use of its devices in life support applications wherein failure or malfunction of a device may lead to personal injury or death. Users of SSO devices in life support applications assume all risks of such use and agree to indemnify SSO against any and all damages resulting from such use. Life support devices are defined as devices or systems which, (a) are intended for surgical implant into the body, or (b) support or sustain life, and (c) whose failure to perform when used properly in accordance with instructions for use can be reasonably expected to result in significant injury to the user, or (d) a critical component in any component of a life support device or system whose failure can be reasonably expected to cause failure of the life support device or system, or to affect its safety or effectiveness.
(c) 2004 Solid State Optronics * San Jose, CA www.ssousa.com * +1.408.293.4600
Page 5 of 5
TR115 rev 1.40 (10/25/2004)


▲Up To Search▲   

 
Price & Availability of TR115

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X